Feasibility study of AI for radiographic DMFT score from panoramic radiographs with external validation

Clinical oral investigations4w ago

An AI pipeline for automatic rDMFT scoring from panoramic radiographs achieved an ICC of 0.84 (95% CI 0.74-0.90) vs. two-dentist reference on external validation, with mean absolute error 2.38, though decayed tooth detection was unreliable.

  • The pipeline was externally validated on 100 panoramic radiographs from an independent hospital.
  • For missing teeth, exact count was correct in 42% of cases but over-called in 15 of 74 complete dentitions.
  • Agreement for filled teeth was high (r=0.90), while decayed tooth detection was unreliable (r=0.34 vs. dentists' 0.16).