Meta-analysis: AI detects femoral head avascular necrosis with high accuracy but limited external validation

Skeletal radiologytoday

Pooled sensitivity 0.888 (95% CI 0.789-0.944) and specificity 0.937 (0.906-0.958) for AI detection of avascular necrosis of the femoral head across nine studies; MRI-based models outperformed radiography (p=0.027). External validation remains limited.

  • Only five of the nine pooled estimates involved external test sets, limiting generalizability of the results.
  • MRI-based AI models showed significantly higher sensitivity than radiography-based models (p=0.027); no differences by disease-stage focus or validation strategy.
  • Risk of bias and between-study heterogeneity were present, and the authors stress the need for prospective, multicenter validation before clinical use.