Chest / ThoracicCardiacAI / InformaticsResearch

AI-Assisted CT Analysis in Pulmonary Hypertension: Systematic Review Finds High Diagnostic Accuracy but Limited Validation

The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantationyesterday

In a systematic review of 17 studies, AI-assisted CT analysis for pulmonary hypertension detection achieved AUCs of 0.66–0.99. However, studies were mostly small, retrospective, and lacked external validation, limiting immediate clinical application.

  • AI-assisted CT yielded AUCs 0.66–0.99 for PH detection, leveraging vascular morphology, cardiac dimensions, perfusion, and parenchymal features.
  • Several studies differentiated CTEPH from acute PE and identified PAH endophenotypes via fibrosis quantification.
  • Methodological heterogeneity and lack of external validation are key barriers to clinical integration.

Automated summary

RadPigeon summaries are original and for information only. They are not clinical advice.