Interventional (IR)Research

Extended Reality Virtual Ruler for PICC Placement Achieves Optimal Tip Positioning in Feasibility Study

Journal of vascular and interventional radiology : JVIRSep 7

In 29 patients, an extended reality (XR) hand ruler achieved optimal PICC tip position in all cases with mean error 0.7 cm. Procedure time and radiation were noninferior to controls. Radiologists gave high ease-of-use ratings (mean Likert 1).

  • All 29 XR-guided peripherally inserted central catheter (PICC) placements achieved optimal tip position at the cavoatrial junction.
  • Procedure time and radiation dose showed no significant difference versus historical controls (p=0.46 and p=0.26, respectively).
  • Mean measurement error of the XR ruler was 0.7±0.9 cm; interventional radiologists strongly agreed it was easy to integrate (mean Likert score 1).

Automated summary

RadPigeon summaries are original and for information only. They are not clinical advice.