Musculoskeletal (MSK)PediatricAI / InformaticsResearch

Multi-reader study benchmarks AI bone age against quantified radiologist variability

Pediatric radiologySep 1

Automated BoneXpert bone age was more accurate than single human readers (mean absolute error 4.8 vs 6.5 months) and had fewer >1.8-year errors (0.7% vs 3.4%) in 1,285 pediatric hand radiographs. Reader variability was higher under age 12 (standard deviation 8.7 vs 4.2 months).

  • Design: 1,285 left-hand/wrist radiographs from five US academic centers, each read by four radiologists from a pool of 22 across nine institutions.
  • Between-institution variability fell from 8.9 to 0.3 months after age adjustment; inter-rater variability was 1.2 months and remained stable after adjustment.
  • A deep-learning algorithm performed similarly to human readers (mean absolute error 6.3 months) with 2.4% substantial deviations (>1.8 years), vs 3.4% for single human readings.

Automated summary

RadPigeon summaries are original and for information only. They are not clinical advice.