Neuro / Head & NeckAI / InformaticsResearch
Automated CT Midline Shift Measurement Matches Expert Accuracy in Multicenter Study
AJNR. American journal of neuroradiologyyesterday
Rapid MLS automated midline shift quantification on noncontrast CT matched expert neuroradiologists (mean absolute error 0.8 vs 0.9 mm, p<0.0001) in a multicenter study of 153 patients with intracranial pathology. The tool slightly underestimated shifts >10 mm.
- Multicenter retrospective study with 153 patients from 13 centers, using three neuroradiologists' consensus as reference.
- Passing-Bablok regression showed agreement (intercept 0.29, slope 0.9); Bland-Altman mean difference 0.2 mm.
- Rapid MLS underestimated MLS values above 10 mm.
Automated summary
RadPigeon summaries are original and for information only. They are not clinical advice.