Body / AbdominalGeneralResearchTrainee
Individualized post-trigger delay bolus tracking improves pancreatic CT enhancement versus fixed 20-second delay
Radiology AI literature (PubMed)1w ago
Individualized post-trigger delay for pancreatic CT yielded higher attenuation (head 126 vs 86 HU, p<0.001; body 125 vs 93 HU) and better subjective quality (84% vs 30% excellent/good) in a prospective 100-patient study.
- Prospective, non-randomized comparison in 100 patients (50 individualized, 50 fixed).
- Post-trigger delays ranged 5–37 sec in the individualized group vs. fixed 20 sec.
- Limitation: non-randomized, single-center, image quality outcomes only; no diagnostic accuracy assessment.
RadPigeon summaries are original and for information only. They are not clinical advice.